4.4 Inverter Output Layout
1.AC output socket
2.AC output connector bar
3.Switch
4.Display screen
1.DC input voltage
2.AC output voltage
3.AC output current
4.AC output frequency
5.Display of fault code
6.Display of machine temperature
4.4.1: Descriptions of fault code of display screen
Fault Code |
Phenomenon |
Cause |
Troubleshooting |
Bell Ringing |
Warning |
BL |
Battery undervoltage |
Too low battery input voltage |
Recharge battery |
Discontinuous cycling after ringing for twice |
1) Short ringing for every about 3 s approximately: Overtemperature alarming; 2) Short ringing for every 7 s approximately: Overload alarming; 3) Short ringing for every 15 s approximately: Undervoltage alarming; |
BO |
Battery overvoltage |
Too high battery input voltage |
Check input power |
Discontinuous cycling after ringing for three times |
|
SC |
Output short circuit |
Output short circuit |
Check output line and load |
Discontinuous cycling after ringing for six times |
|
OC |
Output overcurrent |
Too large output current, immediate protection |
Reduce load |
Discontinuous cycling after ringing for five times |
|
OL |
Output overload |
Too large output current, delay protection |
Reduce load |
||
OH |
Overtemperature protection |
Too high temperature |
Check fan or air duct |
Discontinuous cycling after ringing for four times |
|
EO |
Output line is electrified |
The AC output terminal is connected with equipment with power by mistake |
Check if output line is connected with other powers |
Discontinuous long, medium and short cycles |
|
PN |
Overvoltage of DC bus |
Too high DC bus voltage |
Check input power |
Discontinuous cycles after ringing for three times |
|
NP |
Too low bus voltage |
DC bus undervoltage tripping is detected by startup to prevent a more serious fault |
Check if post-power tube is short circuited |
Discontinuous cycles after ringing for seven times |
|
RS |
Parameter configuration faults |
Restart after parameter configuration |
Restart the machine |
||
EP |
Storage error |
Chip is used for the first time |
|||
RD |
Data reading error |
Not initialized |
|||
SA |
Sampling circuit fault |
Startup self-check error |