{"product_id":"1000w-modified-sine-wave-inverter-12vdc-to-120vac-rbx100012","title":"1000W Modified Sine Wave Inverter 12VDC to 120VAC RBX100012","description":"\u003ch1\u003eWZRELB Modified Sine Wave Inverter\u003c\/h1\u003e\n\u003ch2\u003e1000 Watt Modified Sine Wave Inverter - 12V\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMODIFIED SINE WAVE POWER\u003c\/strong\u003e: Provides 1000W continuous power and 2000W peak surge power for basic AC loads such as chargers, lights, small appliances, vehicle power, travel setups, and basic backup use.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003e12V DC TO 120V AC\u003c\/strong\u003e: This version is configured for 12v DC input and 120VAC \/ 60Hz output for common vehicle, RV, and backup power setups.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eLED DISPLAY \u0026amp; SOFT START\u003c\/strong\u003e: Front LED display helps check operating status, while soft start supports smoother startup for connected appliances.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eMULTIPLE PROTECTION FEATURES\u003c\/strong\u003e: Built-in overload, low-voltage, over-voltage, over-temperature, short-circuit, and reverse-polarity protection help improve operating safety.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eCOMPACT ALUMINUM DESIGN\u003c\/strong\u003e: Aluminum housing supports heat dissipation and durability for vehicle, camping, mobile, and small backup applications.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0078\/9440\/1137\/files\/1_aea9f438-3c84-41e0-a58f-fff16fd3e99c.jpg?v=1784169879\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0078\/9440\/1137\/files\/6_73e97299-06bc-4c40-9625-b455c8463121.jpg?v=1784169879\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0078\/9440\/1137\/files\/5_ceaa4117-489f-4857-918d-710b0d744f9b.jpg?v=1784169879\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0078\/9440\/1137\/files\/3_6341b172-b086-449a-b99a-a1cd520b80af.jpg?v=1784169879\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0078\/9440\/1137\/files\/4_89c5a43e-1646-4b56-9e38-a258d1e50a71.jpg?v=1784169879\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0078\/9440\/1137\/files\/2_dd4e5e87-a8e2-42a9-b299-15b9531fcb1c.jpg?v=1784169879\"\u003e\u003c\/span\u003e\u003cspan style=\"color: #d12929;\"\u003eWarranty: \u003c\/span\u003e12 Months for Non-artificial damage.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2\u003eSpecification\u003c\/h2\u003e\n\u003ctable class=\"tg\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lboi\"\u003eWattage    \u003c\/td\u003e\n\u003ctd class=\"tg-lboi\"\u003e1000w    \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-isc8\"\u003eDC Input Voltage   \u003c\/td\u003e\n\u003ctd class=\"tg-isc8\"\u003e12v\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lboi\"\u003eDC Input Voltage Range   \u003c\/td\u003e\n\u003ctd class=\"tg-lboi\"\u003e10-15v \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-isc8\"\u003eAC Output Voltage   \u003c\/td\u003e\n\u003ctd class=\"tg-isc8\"\u003e120v   \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-isc8\"\u003eFrequency   \u003c\/td\u003e\n\u003ctd class=\"tg-isc8\"\u003e60Hz   \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-isc8\"\u003eOutput Waveform   \u003c\/td\u003e\n\u003ctd class=\"tg-isc8\"\u003eModified sine wave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lboi\"\u003eNo Load Current Draw   \u003c\/td\u003e\n\u003ctd class=\"tg-lboi\"\u003e\u0026lt;15W  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-isc8\"\u003eEfficiency   \u003c\/td\u003e\n\u003ctd class=\"tg-isc8\"\u003e85% -- 90%   \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lboi\"\u003eAC Regulation   \u003c\/td\u003e\n\u003ctd class=\"tg-lboi\"\u003e3%   \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lboi\"\u003eLow Voltage Alarm   \u003c\/td\u003e\n\u003ctd class=\"tg-lboi\"\u003e10.0-10.5v\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-isc8\"\u003eLow Voltage Shut Down   \u003c\/td\u003e\n\u003ctd class=\"tg-isc8\"\u003e\n\u003cspan\u003e9.5-10.0v\u003c\/span\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lboi\"\u003eOver Load   \u003c\/td\u003e\n\u003ctd class=\"tg-lboi\"\u003eShut Off \u0026amp; Recover Manually   \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-d54t\"\u003eOver Voltage Shut Down   \u003c\/td\u003e\n\u003ctd class=\"tg-d54t\"\u003e15.5v   \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-cly1\"\u003eOver Voltage Protection   \u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eShut Off Output Automatically   \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-d54t\"\u003eOver Heat Protection   \u003c\/td\u003e\n\u003ctd class=\"tg-d54t\"\u003eCooling Fans Run When It's Over 120 F   \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-cly1\"\u003eCooling Fans   \u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e1  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-d54t\"\u003eWorking Temperature   \u003c\/td\u003e\n\u003ctd class=\"tg-d54t\"\u003e-10°C TO 50°C \/ -50°F TO 122°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-cly1\"\u003eStorage Temperature   \u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e-30°C TO 70°C \/ -86°F TO 158°F  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-d54t\"\u003eWorking Humidity    \u003c\/td\u003e\n\u003ctd class=\"tg-d54t\"\u003e20% TO 90% RH Non-condensing   \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-cly1\"\u003eStart   \u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eSoft Start   \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-d54t\"\u003eTotal Harmonic Distortion   \u003c\/td\u003e\n\u003ctd class=\"tg-d54t\"\u003eTHD\u0026lt;5%   \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-isc8\"\u003eInverter Size (inch)   \u003c\/td\u003e\n\u003ctd class=\"tg-isc8\"\u003e8.46 x 3.94 x 2.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-lboi\"\u003eNet Weight (pound)   \u003c\/td\u003e\n\u003ctd class=\"tg-lboi\"\u003e1.90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003ch2\u003eLoad performance test\u003c\/h2\u003e\n\u003ch2\u003e\u003ciframe title=\"YouTube Shorts player\" src=\"https:\/\/www.youtube.com\/embed\/hF3aYkjM1mY\" height=\"562\" width=\"100%\"\u003e\u003c\/iframe\u003e\u003c\/h2\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003e\u003cstrong\u003eCan I add a fuse or circuit breaker between the input terminal of the inverter and the battery? If so, what specifications are recommended?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eYes, the following is the calculation of fuse ampere.\u003c\/p\u003e\n\u003cp\u003eContinuous power of the inverter ÷ Lowest input voltage = Fuse ampere, \u003cstrong\u003ee.g.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e 1000W 12V version: recommend a 100Amp fuse (1000W÷10VDC=100Amp)\u003c\/p\u003e\n\u003col start=\"2\"\u003e\n\u003cli\u003e\u003cstrong\u003eWhy did sparks appear on the cable and the inverter terminal when connecting the battery to the inverter?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThis is normal, and it does not mean the inverter is malfunctioning. The inverter has built-in capacitors, so when the battery cable is connected to the inverter input, a small spark may appear as part of the charging process.\u003c\/p\u003e\n\u003col start=\"3\"\u003e\n\u003cli\u003e\u003cstrong\u003eWhy does the inverter's output voltage keep dropping or even shut down automatically when running loads?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eFirst, check whether the fuse or breaker size is correct. Second, make sure the battery cables are thick enough and all supplied cables are used correctly. Third, check whether the battery capacity is too small for the load. Thin cables, long cable runs, or weak battery systems can all cause voltage drop.\u003c\/p\u003e\n\u003col start=\"4\"\u003e\n\u003cli\u003e\u003cstrong\u003eWhy can't the inverter be turned on?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003ePlease fully charge the battery before installing the inverter. When battery power is too low, the inverter may enter low-voltage protection or fail to start.\u003c\/p\u003e\n\u003col start=\"5\"\u003e\n\u003cli\u003e\u003cstrong\u003eWhy can't my inverter run the refrigerator or motor load?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eSome inductive loads may need much higher startup surge than their running power. Before connecting, make sure the appliance startup requirement stays within the inverter's peak surge power. If the load is difficult to start or highly sensitive, a pure sine wave inverter may be the better choice.\u003c\/p\u003e","brand":"WZRELB","offers":[{"title":"Default Title","offer_id":45263812067510,"sku":null,"price":58.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0078\/9440\/1137\/files\/01_43e7785a-dd18-480d-9244-6dad1023643a.jpg?v=1780294142","url":"https:\/\/reliableinverters.com\/products\/1000w-modified-sine-wave-inverter-12vdc-to-120vac-rbx100012","provider":"Pure Sine Wave Inverter","version":"1.0","type":"link"}